Print Back
The P-Trap features solder cups. A major application of the fitting is on the suction line of a refrigeration compressor. The line is looped, by use of the P-Trap, to the floor prior to being run vertically upwards to prevent the drainage of oil back to the compressor during shut-down periods. Additional P-Traps are used for each 20 feet of riser pipe; this prevents high velocity build-up as the oil or liquid begins to return to the compressor during the shut-down period. Please refer to NIBCOmore
Unit of Measure

Specifications

UPC Code

039923320063

All Type of Item

Fitting

All Special Application

Lead-Free*; ACR Air Conditioning / Refrigeration

Description

698 1 CXC SUCTION LINE PTRAP WROT

Type

Trap

Connection Type

C x C

Weight

0.917 lb

Size

1

Material

Copper